Volume 9 , Issue 3 , September 2019 , Pages 281-285
Amar Alhamdi 1 ; Azad Jalal Ali 2 ; Nidham Alhassania 3
1 Division of Cardiology, Alhassani Heart Day Clinic, Sulaimani, Kurdistan Region, Iraq
2 Department of Anesthesia, Shar Teaching Hospital, Sulaimani, Kurdistan Region, Iraq
3 Divisions of Cardiology, Alhassani Heart Day Clinic, Sulaimani, Kurdistan Region, Iraq
We report a case of long-standing persistent atrial fibrillation and bifascular block exposed to synchronized DC- cardioversion which resulted in cardiac arrest, the patient resuscitated including temporary and then permanent pacemaker implantation. The patient recovered fully and stayed in sinus rhythm. Patients with atrial fibrillation and symptomatic bifascular block, exposed to synchronized DC shock to revert into sinus rhythm, should receive either temporary pacing cover for the electrical cardioversion procedure, or should have at least a single ventricular permanent pacemaker prior to cardioverting them into sinus rhythm by applying synchronized DC – shock, as the likelihood of developing sinus arrest and escape rhythm failure is significantly high.